Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 69: 360-365, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32554200

RESUMO

BACKGROUND: The aim of this study is to present midterm results of thoracic endovascular aortic repair (TEVAR) using scalloped or fenestrated custom-made endovascular grafts (CMEGs) in aortic arch Zones 0 and 1. METHODS: A retrospective review of prospectively collected data involving consecutive patients with aortic arch disease treated by scalloped or fenestrated Relay Plus stent grafts (Terumo Aortic, Sunrise, FL) landed in Zones 0 and 1. Patient demographics, operative details, clinical outcomes, and complications were analyzed. RESULTS: Between February 2014 and February 2020, 14 patients (9 male and 5 female) with a median age of 66 years (range 48-84) underwent scalloped or fenestrated TEVAR to preserve flow to the supra-aortic trunks (SATs). In 6 cases the landing zone was Zone 0 and in 8, Zone 1. Target vessels for the scallops were left common carotid artery in 8 cases (Zone 1) and innominate artery (IA) in 1 (Zone 0). All 5 fenestrations were designed to preserve the IA (Zone 0). Technical success was 100% with no endoleaks on completion angiography. One fatal perioperative stroke (7%) occurred in a patient with a fenestration for the IA and atherosclerotic plaques in the arch. During median follow-up of 37.5 (3-72) months, no other patient died, and all the target vessels and cervical revascularizations remained patent. There was no paraplegia, no retrograde dissection, and no other complication. Two patients (14%) with scallops in Zone 1 developed late endoleak: 1 type Ib at 6 months and 1 type Ia endoleak at 12 months. There were no endoleaks at all in the group of fenestrated endografts (Zone 0). CONCLUSIONS: When anatomy allows, endovascular treatment using scalloped or fenestrated CMEGs in Zones 0 and 1 is a feasible technique to treat patients with aortic arch disease involving the SATs.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...